Carrier 58ssc Repair Manual or Schematic
Is there a repair manual available so I can trouble shoot my furnace? Be nice to know what readings I should have at the various test points. The gas appears to come on, but no ignition from the sparking device. Schematic on service door shows Hot Surface Ignitor (110vac at TP4) but I don't have a HSI. I doubt 110vac would be sufficient to spark off the gas. I expect there is a high voltage xfmr somewhere on the circuit board, possibly on the auxilary board that is in the area of TP4 the HSI relay. A schematic of the circuit board would be MOST useful. The manual for your furnace is here: http://www.xpedio.carrier.com/idc/gr...t/58ss-1si.pdf I presume you have a Carrier three wire pilot intermittent ignition system. You should have three wires coming from the pilot burner to a white plug, with the wires being green, yellow and white. Page 5 of the manual describes the sequence of operation of the furnace --- you need to follow that and decide how far the furnace gets before it goes no further. What do you mean when you say the gas appears to come on? Briefly, when the thermostat is turned up, the inducer motor should turn on and spool up. When the pressure switch closes, the gas to the pilot burner and the spark to light the pilot burner should turn on.
Related Posts:
Carrier weathermaker 8000 short cycling as ignition problem
Carrier Weathermaker 8000 short cycling as ignition problemI have a Carrier Weathermaker 8000, 58WAV090-LC, giving a code #34 which results in a code #14 after a few tries. This indicates an ignit...
Carrier oil furnace 58hu100101ca ignition not smooth
Carrier Oil Furnace 58HU100101CA Ignition not SmoothInstalled all new in 1983 with Ducane Oil Burner, Webster fuel pump and Carrier Heat pump by licensed Carrier installer. Underground oil tank wi...
Carrier weathermaker gas furnace intermittent ignition
Carrier Weathermaker, Gas Furnace - Intermittent IgnitionCarrier Weathermaker 8000 - Model #: 58WAV090-GC (circa 1992) For the last 3 seasons, my no ignition problem was solved by cleaning the fla...
Carrier evaporator coil replacement and other considerations
Carrier Evaporator coil replacement and other considerationsI have a 2.5 Ton Carrier Air Conditioner with the Evaporator coil mounted on top of gas furnace. The unit was low on refrigerant, so the...
Carrier boiler clicking
Carrier boiler clickingHello, I have a Carrier series PW83 hot water boiler, most likely installed in 1967 when the house was new. We've owned the home for 8 years, and no problems. Last night, I...