Help rewiring dayton motor for 220v

Help rewiring Dayton motor for 220v


Hello: I have an old Dayton 6K773D 110v/220v electric motor that I'm looking to rewire from 110v to 220v. Unfortunately, it is an older motor which I acquired used and it does not have a wiring diagram anywhere. The terminal block has 4 spade connectors labeled 1 through 4, from bottom to top, plus a ground connection. Connector one is a single connector that is currently wired to the neutral wire going to the plug. Connector 2 is a black wire that runs to the motor (I assume one of the starter winding connectors). Connector 3 is a dual spade connector (bridged) that currently has nothing attached to it. Connector 4 is another dual connector (bridged); one connector has the hot wire going to the plug, and the other connector has another black wire going to the motor (the other starter winding connector?). If I had to guess, I would remove the neutral wire going to connector 1, move the black wire from connector 2 to one of the spades on connector 3, and run my second hot wire to the other spade on connector 3. However, I'd like to get confirmation before I do anything. Thanks in advance. J.B. I cannot find any info on the web. Grainger Industrial Supply carries Dayton motors. You could call Grainger, and see if you can get a phone number to Dayton's tech support department. Another option is to see if a motor re-wind shop will do you a freebee and ring the motor out, or tell you wire it. You may have to remove the motor from its mounts and take it in for the people to look at. I checked the Grainger website, and the part number comes up as a discontinued 2 hp air compresser motor. There is a picture of the motor showing a wiring diagram on the nameplate. Unfortunately, I have a crummy monitor, and can't quite make it out. Take a look, maybe you can. http://www.grainger.com/Grainger/wwg/itemDetailsRender.shtml?ItemId=1611785942 If all else fails, call your local Grainger branch. They should have this information on file. Good luck! Yeah, I can't make it out, either. I'll give Grainger a call. Thanks for the help! J.B. Grainger came through and faxed me a copy of the wiring schematic. I figured I would post it here, since it appears to apply to all K series dual voltage capacitor start Dayton motors. Go here for the schematic: http://www.wrxtra.com/Misc/Electrical/Dayton/


Related Posts:




  • Help needed installing x10 wall switch

    Help needed INSTALLING x10 WALL SWITCHI just recently purchased a bunch of x10 modules for home automation, among them were light switches. It's been about 10 years since I changed a light switch...


  • Help carrier furnace blower motor not coming on no heat

    Help Carrier furnace blower motor not coming on = No heatHello all I have a Carrier 58gsc-080 DB forced air furnace the maunal can be seen at the link below. http://www.xpedio.carrier.com/idc/gr.....


  • Goodman air handler blower motor

    Goodman air handler blower motorHoping to get a little advice. I replaced the blower motor and wheel on my Goodman 5 ton air handler to get rid of a vibration. The blower motor has 2 brown wires g...


  • Help with ceiling fan wiring

    Help with ceiling fan wiringHi all, I'm trying to put up a Turn of the Century (Avalon model) ceiling fan in our bedroom, and ran into a bit of a hiccup. Between the switch box and the ceiling box...


  • Help a dummy wire a thermostat

    Help a dummy wire a thermostatI want to replace a White Rodgers 1f56w-444 with a Honeywell TH8110U1003 Vision Pro on a Heil ntg3075fbg. The White Rodgers wires are not labled in the unit but are i...